specification

Pump Modules

CJ 2000/10/ - 45ltrs/min (10gpm) @ 130 bar (2000 p.s.i) generated by high pressure CAT pump, driven by 11Kw 415v 50Hz motor. Fitted with pre set safety valve, adjustable pressure regulator and pulsation damper. Zinc plated or galvanised fabrication housed under fixed fibreglass lightweight cover.

CJ 2000/20/ - 90ltrs/min (20 gpm) @ 130 bar (2000 p.s.i) generated by 2 off high-pressure CAT pumps, driven by 2 off 11Kw 415v 50Hz motors. Fitted with sealed tamperproof safety valve, adjustable pressure regulator and pulsation damper. Zinc plated or galvanised fabrications housed under fibreglass lightweight cover.

By-laws compliance/water boost set

The water by-laws compliance/boost set is constructed from a 227 Litre plastic tank incorporating the required air gap between stored water level and the town water supply, water inlet float valves and required overflows.

One off centrifugal boost pump is connected to the storage tank to supply the high-pressure triplex Cat pump located in the pump module with water at the correct flow and pressure for optimum performance and reliability.

Water level is controlled by means of a float valve. A low level float switch is fitted in the storage tank to stop all pumps from operating. The tank and associated pipe work is adequately protected against frost damage.

Detergent Application

There are two options offered for the application of detergents - before high-pressure washing (foam application) and during high-pressure washing (detergent injection).

Remote Cable Winding Drum

For use with pit mounted installations and where it is not practical to locate pump module and drive unit in the same area.

Hot Water Module

Purpose built self-contained 3-pass heat exchanger to provide 45 ltrs/min or 90 ltrs/min at 70°C oil or gas fired. Fitted with Nu-Way or Selectos burners housed in lightweight fibreglass cover.
Note: all exhaust gas flue ductwork is to be supplied and installed by the customer.

Remote Cable Winding Drum

For use with pit mounted installations and where it is not practical to locate pump module and drive unit in the same area.

Hot Water Module

Purpose built self-contained 3-pass heat exchanger to provide 45 ltrs/min or 90 ltrs/min at 70°C oil or gas fired. Fitted with Nu-Way or Selectos burners housed in lightweight fibreglass cover.
Note: all exhaust gas flue ductwork is to be supplied and installed by the customer.

CAP002 Automatic Frost Protection

If temperatures fall below the pre determined value set on the frost stat, a solenoid valve is operated allowing all water to be blown from the high pressure hoses by compressed air for an adjustable time. The activation of the frost protection system disables the use of the equipment until the frost stat has reset.

CHG001 Hand Lance System

Trigger operated hand lance complete with high pressure hose for manual cleaning. High pressure water is diverted from the pump module for use with the hand lance.

CPR001 Pressure Reduction

Automatically reduces the discharge pressure from the high pressure pumps by the operation of a high-pressure solenoid valve located within the pump module. Operation of the solenoid valve is controlled at the operators control panel and can be activated at any point during an automatic cycle to avoid any sensitive areas.

Vehicle Guides

Two versions of wheel guide are available.

  1. Conventional tubular steel construction galvanised and fixed directly to the floor to aid correct vehicle location on the wash pad.
  2. Armco crash barrier construction fitted to assist with correct vehicle alignment and prevent damage to the Chassijet 2000 rails and trolley.

Special Purpose Plant Room

if the proposed installation has no existing facility to house the pump module and other associated plant then a purpose built plant room should be specified. The plant room will be fitted with heating and lighting and all items of plant prior to delivery to site.

Water Reclamation Unit

Shall be supplied installed and serviced by a specialist contractor with extensive experience of supplying water recycling systems for this type of application. The system shall comprise of the following components:

  • Stainless steel storage tanks
  • Stainless steel gravel filter bed and intelligent backwashing
  • Stainless steel sand filter bed with intelligent backwashing
  • Skid mounted pumps and controls
  • Hydro cyclone
  • Hydro cyclone underflow monitor with alarm and automatic fresh water bypass
  • Reclaim odour control dosing system
  • Anti foam dosing system
  • Adjustable aeration system
  • Automatic sump tank refill (after sludge gulping)
  • Water circulation facility
  • Biological filtration bed
  • Ph control system